top of page

Automatic hematological  parser  expert class

ADVIA 2120 i

Intelligent hematology analyzers designed for high-throughput laboratories. The systems combine advanced laser flow cytometry with intelligent process control, providing the highest accuracy of cell differentiation and continuous operation

Why choose Atellica HEMA?

Expert accuracy 5-diff:

The use of multiparametric laser analysis allows achieving exceptional accuracy in calculating the leukocyte formula, even in complex clinical cases.

Scalable performance:

The systems are designed to operate 24/7. Rapid processing of large sample volumes allows the laboratory to maintain consistently low time-to-results (TAT)

New level automation:

From automatic recalculation of pathological samples to built-in quality control systems, these devices minimize manual manipulations and the risk of errors.

Integrated efficiency:

Easy integration into laboratory information systems (LIS) and automated lines makes these models the “heart” of the modern hematology laboratory

Technical specifications

Differential results
(absolute and%)

LYM, MON, NEU, EOS, BAS, ALY, LIC, IMG, IML, IMM

PLT results (optical)

PLTO, LPF

Reticulocyte results

WBC, RBC, HB *, HCT, MCV, MCH, MCHC, CHCM, RDW, HDW, CH, CHDW, PLT

Liquid analysis results
(cerebrospinal, serous and synovial fluids)

BFWBC, BFRBC, absolute and % BFMN, BFPN

Capacity

CBC

120 samples/hour

Differential results
(absolute and%)

Shift to the left, atypical lymphocytes, blasts, immature granulocytes,

myeloperoxidase deficiency

RET

60 samples/hour

DIR (including NRBC)

60 samples/hour

CBR

60 samples/hour

DIFF_LV

60 samples/hour

RBC_PLTO

60 samples/hour

Modes / volumes

Automatic download

120 tubes (12 racks of 10 tubes)

Closed test tube, manual  regime

1 test tube

Automatic mode (closed tube)

110 μl

STAT mode (closed/open tube)

110 μl

Measuring range

WBC

0.1–300 x 103/mm3

RBC

0.2–8 x 106/mm3

PLT

(HGB >2) 7–2500 x 103/mm3
(HGB <2) 7–5000 x 103/mm3

HGB

0.8–24 g/dL

RET%

0.2 - 24.5%

Data management

Database

150 (15 tripods x 10 cuvettes)

Ability to view and edit

Atellica Data Manager allows you to create custom windows, reports, and ranges based on age and gender for normal range, rerun, and delta check criteria.

Quality Control (QC) Management

Z-test, construction of Levy-Jennings graphs, automatic application of Westgard rules and calculation of moving average by patients

Dimensions

Atellica HEMA 570 and 580

73 x 87 x 67 cm

Automatic reading

barcodes

44 x 91 x 72 cm

Results

CBC results

WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, MIC%, MAC%, PLT, MPV, PCT, PDW, NRBC (absolute and %) TNC, P-LCC and P-LCR

bottom of page